- Home
- Product Categories
Product Categories
Product Listing
-
Product Part
Description:
Shim-pack VP series is designed for the development and validation of analytical methods.
OUT OF STOCKShim-pack VP series is designed for the development and validation of analytical methods.
-
Product Part
Description:
Shim-pack VP series is designed for the development and validation of analytical methods.
OUT OF STOCKShim-pack VP series is designed for the development and validation of analytical methods.
-
Product Part
Description:
Shim-pack VP series is designed for the development and validation of analytical methods.
OUT OF STOCKShim-pack VP series is designed for the development and validation of analytical methods.
-
Product Part
Description:
Shim-pack VP series is designed for the development and validation of analytical methods.
LOW STOCKShim-pack VP series is designed for the development and validation of analytical methods.
-
Product Part
Description:
Shim-pack VP series is designed for the development and validation of analytical methods.
OUT OF STOCKShim-pack VP series is designed for the development and validation of analytical methods.
-
Product Part
Description:
Shim-pack VP series is designed for the development and validation of analytical methods.
OUT OF STOCKShim-pack VP series is designed for the development and validation of analytical methods.
-
Product Part
Description:
*1 Note that a delay volume equivalent to the internal volume of the product occurs if the product is installed downstream of the gradient mixer or the confluence of two pumps. * The product service life differs according to analysis conditions, such as the mobile phase used. * Do not use the product when using a mass spectrometer as the detector, as the product may cause bleed noise. * In analysis using an ion-pairing reagent, the ion-pairing reagent may be retained in the product, influencing the retention time and peak shape. * Before connecting the analytical column, be sure to thoroughly clean the flow path with mobile phase (close to the final concentration for gradient analysis). * Note that some impurities may not be removed. * When performing high-pressure analysis exceeding 35 MPa with a UHPLC system, connect the gradient mixer to the Ghost Trap DS-HP with pipe for UHPLC (e.g. 228-53137-97).
IN STOCK*1 Note that a delay volume equivalent to the internal volume of the product occurs if the product is installed downstream of the gradient mixer or the confluence of two pumps. * The product service life differs according to analysis conditions, such as the mobile phase used. * Do not use the product when using a mass spectrometer as the detector, as the product may cause bleed noise. * In analysis using an ion-pairing reagent, the ion-pairing reagent may be retained in the product, influencing the retention time and peak shape. * Before connecting the analytical column, be sure to thoroughly clean the flow path with mobile phase (close to the final concentration for gradient analysis). * Note that some impurities may not be removed. * When performing high-pressure analysis exceeding 35 MPa with a UHPLC system, connect the gradient mixer to the Ghost Trap DS-HP with pipe for UHPLC (e.g. 228-53137-97).
-
Product Part
Description:
Shim-pack MAqC-ODS I reversed-phase columns are packed with a silica gel containing metal and bonded octadecylsilyl group. In addition to the hydrophobic characteristics of the ODS, the metal content also provides cation-exchange effects. This increases the retention of basic compounds. Therefore, this allows use with only a buffer solution as the mobile phase for analyses that previously required using an ion pair reagent and enables using gradient elution. These characteristics are especially beneficial for analyzing water soluble vitamins and pharmaceuticals that contain a large amount of basic compounds. * To use this column efficiently: 1) To increase the retention of basic compounds, please use a buffer solution within the pH 2 to 4 range. 2) In the case of a basic substance tailing, it may be possible to improve the peak shape by increasing the salt concentration of a buffer solution. 3) The elution of basic compounds is faster by increasing the salt concentration, and it is possible to adjust retention by salt concentration.
LOW STOCKShim-pack MAqC-ODS I reversed-phase columns are packed with a silica gel containing metal and bonded octadecylsilyl group. In addition to the hydrophobic characteristics of the ODS, the metal content also provides cation-exchange effects. This increases the retention of basic compounds. Therefore, this allows use with only a buffer solution as the mobile phase for analyses that previously required using an ion pair reagent and enables using gradient elution. These characteristics are especially beneficial for analyzing water soluble vitamins and pharmaceuticals that contain a large amount of basic compounds. * To use this column efficiently: 1) To increase the retention of basic compounds, please use a buffer solution within the pH 2 to 4 range. 2) In the case of a basic substance tailing, it may be possible to improve the peak shape by increasing the salt concentration of a buffer solution. 3) The elution of basic compounds is faster by increasing the salt concentration, and it is possible to adjust retention by salt concentration.
-
Product Part
Description:
Shim-pack MAqC-ODS I reversed-phase columns are packed with a silica gel containing metal and bonded octadecylsilyl group. In addition to the hydrophobic characteristics of the ODS, the metal content also provides cation-exchange effects. This increases the retention of basic compounds. Therefore, this allows use with only a buffer solution as the mobile phase for analyses that previously required using an ion pair reagent and enables using gradient elution. These characteristics are especially beneficial for analyzing water soluble vitamins and pharmaceuticals that contain a large amount of basic compounds. * To use this column efficiently: 1) To increase the retention of basic compounds, please use a buffer solution within the pH 2 to 4 range. 2) In the case of a basic substance tailing, it may be possible to improve the peak shape by increasing the salt concentration of a buffer solution. 3) The elution of basic compounds is faster by increasing the salt concentration, and it is possible to adjust retention by salt concentration.
OUT OF STOCKShim-pack MAqC-ODS I reversed-phase columns are packed with a silica gel containing metal and bonded octadecylsilyl group. In addition to the hydrophobic characteristics of the ODS, the metal content also provides cation-exchange effects. This increases the retention of basic compounds. Therefore, this allows use with only a buffer solution as the mobile phase for analyses that previously required using an ion pair reagent and enables using gradient elution. These characteristics are especially beneficial for analyzing water soluble vitamins and pharmaceuticals that contain a large amount of basic compounds. * To use this column efficiently: 1) To increase the retention of basic compounds, please use a buffer solution within the pH 2 to 4 range. 2) In the case of a basic substance tailing, it may be possible to improve the peak shape by increasing the salt concentration of a buffer solution. 3) The elution of basic compounds is faster by increasing the salt concentration, and it is possible to adjust retention by salt concentration.
-
Product Part
Description:
Shim-pack MC C18 column with 1.9 μm UHPLC particle achieves excellent separation and peak shape. The high pressure rating of 70 MPa allows these columns to be compatible with a range of mobile phase flow rates from 1 to dozens of μL per minute. The metal coordinative adsorption is suppressed by deactivating the column parts in contact with the solution. Both small and large molecule compounds, such as peptides, can be analyzed. Excellent durability can be achieved even if the biological sample analysis.
OUT OF STOCKShim-pack MC C18 column with 1.9 μm UHPLC particle achieves excellent separation and peak shape. The high pressure rating of 70 MPa allows these columns to be compatible with a range of mobile phase flow rates from 1 to dozens of μL per minute. The metal coordinative adsorption is suppressed by deactivating the column parts in contact with the solution. Both small and large molecule compounds, such as peptides, can be analyzed. Excellent durability can be achieved even if the biological sample analysis.
-
Product Part
Description:
Shim-pack MC C18 column with 1.9 μm UHPLC particle achieves excellent separation and peak shape. The high pressure rating of 70 MPa allows these columns to be compatible with a range of mobile phase flow rates from 1 to dozens of μL per minute. The metal coordinative adsorption is suppressed by deactivating the column parts in contact with the solution. Both small and large molecule compounds, such as peptides, can be analyzed. Excellent durability can be achieved even if the biological sample analysis.
OUT OF STOCKShim-pack MC C18 column with 1.9 μm UHPLC particle achieves excellent separation and peak shape. The high pressure rating of 70 MPa allows these columns to be compatible with a range of mobile phase flow rates from 1 to dozens of μL per minute. The metal coordinative adsorption is suppressed by deactivating the column parts in contact with the solution. Both small and large molecule compounds, such as peptides, can be analyzed. Excellent durability can be achieved even if the biological sample analysis.
-
Product Part
Description:
Shim-pack MC C18 column with 1.9 μm UHPLC particle achieves excellent separation and peak shape. The high pressure rating of 70 MPa allows these columns to be compatible with a range of mobile phase flow rates from 1 to dozens of μL per minute. The metal coordinative adsorption is suppressed by deactivating the column parts in contact with the solution. Both small and large molecule compounds, such as peptides, can be analyzed. Excellent durability can be achieved even if the biological sample analysis.
OUT OF STOCKShim-pack MC C18 column with 1.9 μm UHPLC particle achieves excellent separation and peak shape. The high pressure rating of 70 MPa allows these columns to be compatible with a range of mobile phase flow rates from 1 to dozens of μL per minute. The metal coordinative adsorption is suppressed by deactivating the column parts in contact with the solution. Both small and large molecule compounds, such as peptides, can be analyzed. Excellent durability can be achieved even if the biological sample analysis.