Technique Categories



Product Listing

  • Product Part
    Description:

    Polar PLOT column, incorporating divinylbenzene ethylene glycol / dimethylacrylate. Highest polarity porous polymer column in Shimadzu PLOT columns. Highly inert for the analysis of polar and nonpolar compounds. Ideal for trace H2S, COS, and mercaptans in hydrocarbon streams. Temp. range up 190 °C Similar phases: HP-PLOT U, CP-PoraPLOT U, CP-PoraBOND U, Rt-U-BOND

    OUT OF STOCK

    Polar PLOT column, incorporating divinylbenzene ethylene glycol / dimethylacrylate. Highest polarity porous polymer column in Shimadzu PLOT columns. Highly inert for the analysis of polar and nonpolar compounds. Ideal for trace H2S, COS, and mercaptans in hydrocarbon streams. Temp. range up 190 °C Similar phases: HP-PLOT U, CP-PoraPLOT U, CP-PoraBOND U, Rt-U-BOND

  • Product Part
    Description:

    Extend column lifetime. Excellent inertness—obtain lower detection limits for active compounds. Sharper chromatographic peaks by utilizing retention gap technology. Maximum temperature: 360 °C.

    OUT OF STOCK

    Extend column lifetime. Excellent inertness—obtain lower detection limits for active compounds. Sharper chromatographic peaks by utilizing retention gap technology. Maximum temperature: 360 °C.

  • Product Part
    Description:

    Extend column lifetime. Excellent inertness—obtain lower detection limits for active compounds. Sharper chromatographic peaks by utilizing retention gap technology. Maximum temperature: 360 °C.

    OUT OF STOCK

    Extend column lifetime. Excellent inertness—obtain lower detection limits for active compounds. Sharper chromatographic peaks by utilizing retention gap technology. Maximum temperature: 360 °C.

  • Product Part
    Description:

    Highly polar phase; biscyanopropyl polysiloxane—not bonded Stationary phase selectivity optimized for isomer separation to ensure accurate quantification of critical cis/trans FAMEs. Application-specific QC test guarantees consistent, reliable performance for AOAC 996.06 and AOCS Ce 1j-07 methods. Excellent sample capacity; no peak distortion means easy, accurate peak integration. Similar phases: HP-88, CP Sil 88, SBP-2560, Rt-2560

    OUT OF STOCK

    Highly polar phase; biscyanopropyl polysiloxane—not bonded Stationary phase selectivity optimized for isomer separation to ensure accurate quantification of critical cis/trans FAMEs. Application-specific QC test guarantees consistent, reliable performance for AOAC 996.06 and AOCS Ce 1j-07 methods. Excellent sample capacity; no peak distortion means easy, accurate peak integration. Similar phases: HP-88, CP Sil 88, SBP-2560, Rt-2560

  • Product Part
    Description:

    Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane General -purpose columns for drugs, solvent impur i t ies, pesticides,hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles. Equivalent to USP G27 and G36 phases. Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5, Rtx-5

    OUT OF STOCK

    Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane General -purpose columns for drugs, solvent impur i t ies, pesticides,hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles. Equivalent to USP G27 and G36 phases. Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5, Rtx-5

  • Product Part
    Description:

    Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane General -purpose columns for drugs, solvent impur i t ies, pesticides,hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles. Equivalent to USP G27 and G36 phases. Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5, Rtx-5

    OUT OF STOCK

    Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane General -purpose columns for drugs, solvent impur i t ies, pesticides,hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles. Equivalent to USP G27 and G36 phases. Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5, Rtx-5

  • Product Part
    Description:

    Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane General -purpose columns for drugs, solvent impur i t ies, pesticides,hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles. Equivalent to USP G27 and G36 phases. Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5, Rtx-5

    OUT OF STOCK

    Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane General -purpose columns for drugs, solvent impur i t ies, pesticides,hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles. Equivalent to USP G27 and G36 phases. Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5, Rtx-5