- Home
- Technique Categories
Technique Categories
Product Listing
-
-
-
Product Part
Description:
Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane Dedicated columns for amines and other basic compounds, including alkylamines, diamines, triamines, ethanolamines, and nitrogen-containing heterocyclics.
OUT OF STOCKLow-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane Dedicated columns for amines and other basic compounds, including alkylamines, diamines, triamines, ethanolamines, and nitrogen-containing heterocyclics.
-
Product Part
Description:
Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane Dedicated columns for amines and other basic compounds, including alkylamines, diamines, triamines, ethanolamines, and nitrogen-containing heterocyclics.
OUT OF STOCKLow-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane Dedicated columns for amines and other basic compounds, including alkylamines, diamines, triamines, ethanolamines, and nitrogen-containing heterocyclics.
-
Product Part
Description:
Application-specific columns, specially tested for triglycerides. The SH-65TG phase resolves triglycerides by degree of unsaturation as well as by carbon number.
OUT OF STOCKApplication-specific columns, specially tested for triglycerides. The SH-65TG phase resolves triglycerides by degree of unsaturation as well as by carbon number.
-
Product Part
Description:
Application-specific columns, specially tested for triglycerides. The SH-65TG phase resolves triglycerides by degree of unsaturation as well as by carbon number.
OUT OF STOCKApplication-specific columns, specially tested for triglycerides. The SH-65TG phase resolves triglycerides by degree of unsaturation as well as by carbon number.
-
Product Part
Description:
Polar PLOT column, incorporating divinylbenzene ethylene glycol / dimethylacrylate. Highest polarity porous polymer column in Shimadzu PLOT columns. Highly inert for the analysis of polar and nonpolar compounds. Ideal for trace H2S, COS, and mercaptans in hydrocarbon streams. Temp. range up 190 °C Similar phases: HP-PLOT U, CP-PoraPLOT U, CP-PoraBOND U, Rt-U-BOND
OUT OF STOCKPolar PLOT column, incorporating divinylbenzene ethylene glycol / dimethylacrylate. Highest polarity porous polymer column in Shimadzu PLOT columns. Highly inert for the analysis of polar and nonpolar compounds. Ideal for trace H2S, COS, and mercaptans in hydrocarbon streams. Temp. range up 190 °C Similar phases: HP-PLOT U, CP-PoraPLOT U, CP-PoraBOND U, Rt-U-BOND
-
-
-
Product Part
Description:
Mid-polarity phase: Crossbond™ 25% diphenyl / 75% dimethyl polysiloxane General-purpose columns for volatile compounds, flavor compounds, alcoholic beverages.
OUT OF STOCKMid-polarity phase: Crossbond™ 25% diphenyl / 75% dimethyl polysiloxane General-purpose columns for volatile compounds, flavor compounds, alcoholic beverages.
-
Product Part
Description:
Non-polar phase: Crossbond™ 100% dimethyl polysiloxane General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semi-volatiles, pesticides, oxygenates. Equivalent to USP G1, G2, G38 phases. Similar phases: HP-1, DB-1, CP Sil 5 CB, SPB-1, Rtx-1
OUT OF STOCKNon-polar phase: Crossbond™ 100% dimethyl polysiloxane General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semi-volatiles, pesticides, oxygenates. Equivalent to USP G1, G2, G38 phases. Similar phases: HP-1, DB-1, CP Sil 5 CB, SPB-1, Rtx-1
-
Product Part
Description:
Application-specific columns for volatile organic pollutants. Excellent for U.S. EPA Method 8021 compounds. The SH-VRX stationary phase and optimized column dimensions provide low bleed, excellent resolution, and fast analysis times for volatile compounds.
OUT OF STOCKApplication-specific columns for volatile organic pollutants. Excellent for U.S. EPA Method 8021 compounds. The SH-VRX stationary phase and optimized column dimensions provide low bleed, excellent resolution, and fast analysis times for volatile compounds.








