Technique Categories



Product Listing

  • Product Part
    Description:

    Mid-polarity phase: Crossbond™ 6% cyanopropylphenyl / 94% dimethyl polysiloxane Application-specific columns for volatile organic pollutants. Recommended in U.S. EPA methods for volatile organic pollutants. Equivalent to USP G43 phase. Similar phases: HP-624, DB-624, DB-624 UI, VF-624ms, SPB-1301

    OUT OF STOCK

    Mid-polarity phase: Crossbond™ 6% cyanopropylphenyl / 94% dimethyl polysiloxane Application-specific columns for volatile organic pollutants. Recommended in U.S. EPA methods for volatile organic pollutants. Equivalent to USP G43 phase. Similar phases: HP-624, DB-624, DB-624 UI, VF-624ms, SPB-1301

  • Product Part
    Description:

    Non-polar phase: Crossbond™ 100% dimethyl polysiloxane General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semi-volatiles, pesticides, oxygenates. Equivalent to USP G1, G2, G38 phases. Similar phases: HP-1, DB-1, CP Sil 5 CB, SPB-1, Rtx-1   Integrated Guard Columns No leaks for a more robust method. No column connections for easier, faster maintenance. No peak distortions due to connector dead volume and thermal capacity. For column without Integra-Guard column, please refer to 221-75732-30

    OUT OF STOCK

    Non-polar phase: Crossbond™ 100% dimethyl polysiloxane General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semi-volatiles, pesticides, oxygenates. Equivalent to USP G1, G2, G38 phases. Similar phases: HP-1, DB-1, CP Sil 5 CB, SPB-1, Rtx-1   Integrated Guard Columns No leaks for a more robust method. No column connections for easier, faster maintenance. No peak distortions due to connector dead volume and thermal capacity. For column without Integra-Guard column, please refer to 221-75732-30

  • Product Part
    Description:

    Tested with a basic amine test mix. Excellent inertness for basic compounds. Recommended for use with SH-5 Amine, SH-35 Amine, SH-Volatile Amine, and SH-PolarX capillary columns. Batch test chromatogram included. Maximum temperature: 315 °C. Chemists using guard columns in the analyses of basic compounds frequently observe peak tailing and low recovery. This happens because conventionally deactivated tubing surfaces can be adsorptive to basic compounds. Shimadzu offers basedeactivated guard columns, as well as base-deactivated inlet liners, for completely inert sample pathways.

    OUT OF STOCK

    Tested with a basic amine test mix. Excellent inertness for basic compounds. Recommended for use with SH-5 Amine, SH-35 Amine, SH-Volatile Amine, and SH-PolarX capillary columns. Batch test chromatogram included. Maximum temperature: 315 °C. Chemists using guard columns in the analyses of basic compounds frequently observe peak tailing and low recovery. This happens because conventionally deactivated tubing surfaces can be adsorptive to basic compounds. Shimadzu offers basedeactivated guard columns, as well as base-deactivated inlet liners, for completely inert sample pathways.

  • Product Part
    Description:

    Tested with a basic amine test mix. Excellent inertness for basic compounds. Recommended for use with SH-5 Amine, SH-35 Amine, SH-Volatile Amine, and SH-PolarX capillary columns. Batch test chromatogram included. Maximum temperature: 315 °C. Chemists using guard columns in the analyses of basic compounds frequently observe peak tailing and low recovery. This happens because conventionally deactivated tubing surfaces can be adsorptive to basic compounds. Shimadzu offers basedeactivated guard columns, as well as base-deactivated inlet liners, for completely inert sample pathways.

    OUT OF STOCK

    Tested with a basic amine test mix. Excellent inertness for basic compounds. Recommended for use with SH-5 Amine, SH-35 Amine, SH-Volatile Amine, and SH-PolarX capillary columns. Batch test chromatogram included. Maximum temperature: 315 °C. Chemists using guard columns in the analyses of basic compounds frequently observe peak tailing and low recovery. This happens because conventionally deactivated tubing surfaces can be adsorptive to basic compounds. Shimadzu offers basedeactivated guard columns, as well as base-deactivated inlet liners, for completely inert sample pathways.

  • Product Part
    Description:

    Tested with a basic amine test mix. Excellent inertness for basic compounds. Recommended for use with SH-5 Amine, SH-35 Amine, SH-Volatile Amine, and SH-PolarX capillary columns. Batch test chromatogram included. Maximum temperature: 315 °C. Chemists using guard columns in the analyses of basic compounds frequently observe peak tailing and low recovery. This happens because conventionally deactivated tubing surfaces can be adsorptive to basic compounds. Shimadzu offers basedeactivated guard columns, as well as base-deactivated inlet liners, for completely inert sample pathways.

    OUT OF STOCK

    Tested with a basic amine test mix. Excellent inertness for basic compounds. Recommended for use with SH-5 Amine, SH-35 Amine, SH-Volatile Amine, and SH-PolarX capillary columns. Batch test chromatogram included. Maximum temperature: 315 °C. Chemists using guard columns in the analyses of basic compounds frequently observe peak tailing and low recovery. This happens because conventionally deactivated tubing surfaces can be adsorptive to basic compounds. Shimadzu offers basedeactivated guard columns, as well as base-deactivated inlet liners, for completely inert sample pathways.

  • Product Part
    Description:

    Polar polyethylene glycol deactivation Tested with a comprehensive test mix to ensure high inertness. Polyethylene glycol deactivation layer provides optimum wettability for polar compounds. Minimize peak splitting when using polar solvents such as methanol or water. Compatible with SH-PolarWax, SH-225 and SH-2330 capillary columns. Maximum temperature: 280 °C.

    OUT OF STOCK

    Polar polyethylene glycol deactivation Tested with a comprehensive test mix to ensure high inertness. Polyethylene glycol deactivation layer provides optimum wettability for polar compounds. Minimize peak splitting when using polar solvents such as methanol or water. Compatible with SH-PolarWax, SH-225 and SH-2330 capillary columns. Maximum temperature: 280 °C.

  • Product Part
    Description:

    Polar polyethylene glycol deactivation Tested with a comprehensive test mix to ensure high inertness. Polyethylene glycol deactivation layer provides optimum wettability for polar compounds. Minimize peak splitting when using polar solvents such as methanol or water. Compatible with SH-PolarWax, SH-225 and SH-2330 capillary columns. Maximum temperature: 280 °C.

    OUT OF STOCK

    Polar polyethylene glycol deactivation Tested with a comprehensive test mix to ensure high inertness. Polyethylene glycol deactivation layer provides optimum wettability for polar compounds. Minimize peak splitting when using polar solvents such as methanol or water. Compatible with SH-PolarWax, SH-225 and SH-2330 capillary columns. Maximum temperature: 280 °C.

  • Product Part
    Description:

    Midpolarity Crossbond™ phase General-purpose columns for alcohols, oxygenates, PCB congeners (e.g., Aroclor mixes), and pesticides. Equivalent to USP G46 phase. 4.5" standard coil diameter. Similar phase: DB-PS1701

    OUT OF STOCK

    Midpolarity Crossbond™ phase General-purpose columns for alcohols, oxygenates, PCB congeners (e.g., Aroclor mixes), and pesticides. Equivalent to USP G46 phase. 4.5" standard coil diameter. Similar phase: DB-PS1701